FSL Reference Manual for Print Servers
Appendix Section - FSL Commands for IBM 3270 emulation
20
T(est) Functions
Six different tests may be run via the line. Use the following syntax:
%T<test number>
Test Number Test
1 Offline HEX Dump
2 Online HEX Dump
3 ASCII HEX dump
4 Print out settings
5 Print out character sets
6 Cancel Test 3 (On-line ASCII HEX dump)
Test 4 can also be generated via the TEST key on the interface's rear panel. Test 3 is
terminated by pressing the TEST key on the rear panel.
Z Function (Sending user-defined strings)
This function is used for sending user-defined strings (up to 8 strings can be defined -
see FSL 61). Use the following syntax:
%Z<string number>
W Function (Bar code printing)
This function is used for sending bar codes (up to 8 bar codes can be defined - see FSL
59). Use the following syntax:
%W<no><barcode data>%
X Functions (Storing and restoring settings)
The X commands allow you to store the temporarily defined settings or to overwrite these
settings by reading the power up default settings. You may also restore the settings to
factory default.
%X1 Saves temporarily defined settings as power-up settings.
%X3 Reads and activates factory default settings.
%X4 Reads and activates power-up default settings.
Zobrazit stránku 19