65
can be used within one label format. It can be set as the arbitrary positions of a label format.
While use of stored formats will reduce transmission time, no formatting time is saved since the
ZPL® format being recalled was saved as text strings which need to be formatted at print time.
Format: ^XFd:o,x
Parameters:
d = source device of stored image
Accepted Values: up to 8 alphanumeric characters
Default Value: search priority(R:,B:,E:,Z: )
o = name of stored image
Accepted Values: up to 8 alphanumeric characters
Default Value: UNKNOWN
x = image extension
Fixed Value:.ZPL®
^ST
Set Time/Date(for Real Time Clock)
Description:
The ^ST command sets the time and date of the Real Time Clock.
Format:^STa,b,c,d,e,f,g
Parameters:
a = month
Accepted Values:01 to 12
Default Value:current month
b = day
Accepted Values:01 to 31
Default Value:current day
c = year
Accepted Values:1998 to 2097
Default Value:current year
d = hour
Accepted Values:00 to 23
Default Value:current hour
e = minute
Accepted Values:00 to 59
Zobrazit stránku 64